Aquatic Industries, Inc.
7
Note: The bath should remain in its shipping carton until time of installation.
1. Literature dimensions are for reference only. Installation dimensions should be taken directly from the tub. An access
be made through the ceiling below.
IT IS THE INSTALLER’S RESPONSIBILITY TO PROVIDE SUFFICIENT SERVICE ACCESS.
MAKE ABSOLUTELY CERTAIN THAT ACCESS PANELS AND/OR SERVICE OPENINGS ARE PROPERLY
PLACED AND THAT ALL POSSIBLE AREAS WHERE SERVICE MAY BE REQUIRED ARE ACCESSIBLE.
2. Install the drain fitting to the bath. Clearance may be needed for the drain by cutting away the subfloor (where
possible) or by blocking below the tub as may be required.
WARNING: FACTORY SKIRTS DO NOT ALLOW FOR BLOCKING UP OF THE TUB BASE. All blocking must be
solid and provide uniform support to the tub base.
PLEASE NOTE: LuxeAir versions with the black ABS support bases need to be set in a bed of mortar. This will
help in leveling the tub on uneven floors and will help in reducing vibrations and noise.
3. Tub must rest entirely on all leveling feet or ABS Support Base. DO NOT SUPPORT THE WEIGHT OF THE TUB
BY THE RIM.
leveled sub floor. Secure the unit by fastening the bottom feet to the sub floor with any construction adhesive caulk.
4. Frame out under the tub rim as shown in one of the illustrations below. NOTE:
be constructed as required (see Diagram 1A, 1B and 1C
should allow for wall sheathing material to run full length to the floor (see Diagram1D). Install tub firmly against
NOTE: Watertight installation of the drain and overflow is the installer’s responsibility. Drain and/or overflow
leakage is not included in the warranty of this product.
STRUCTURAL PREPARATION:
WARNING: ALL ELECTRICAL CONNECTIONS SHOULD BE MADE BY A LOCALLY LICENSED ELECTRICIAN.
1D Wall Installation 1E Sunken Installation
1B Ledge Installation - 2 1C Apron Installation
1A Ledge Installation - 1
INSTALLATION INSTRUCTIONS