INSTALLATION INSTRUCTIONS
WARNING: 

WARNING: 
THE FOLLOWING:
DANGER: RISK OF ELECTRIC SHOCK!
GFCIs are not supplied, however we do specify their use.
All known code authorities require GFCIs.
LuxeAir baths will need to be hard-wired to the outlets provided. See the following directions and diagram on page 12.
Two junction boxes will be mounted to the frame of the whirlpool. One of the two boxes will have one outlet and will be


wire to the neutral side of the receptacle and the green wire to ground. Replace the cover and plug in the blower. (See
diagram on page 12).

Run Romex 14/3 with ground from a 15 amp 2-pole GFCI breaker (not supplied) located in the breaker panel. Connect
the white wire (neutral) to both neutrals of the two outlets. Connect the red wire (hot) to the hot terminal of the outlet

wire (ground) to the ground terminal of the outlet. Replace the cover of the junction box. Find the pump cord and plug

on page 12).
CAUTION: Before use of the pump and heater, test the GFCI for proper operation. The pump and heater should
turn off when the GFCI “Test” button is pushed.