Maintenance Instructions
CLEANING/
CHECKING/SERVICING
Hydrostatic Transmission Cooling Fins
Keeping the cooling fins on the hydrostatic transmis-
sions clean and free of obstruction is essential to
avoid overheating the transmission fluid and short-
ening transmission life. The cooling fins should be
checked every 100 hours; and cleaned if necessary.
To clean the fins, use compressed air and/or a pres-
sure washer. The cooling fins extend all the way
around the housing -- the fins underneath need to be
clean as well as the more visible fins above. Also,
pay close attention to the area under the drive pulley.
IMPORTANT: In case an oil leak develops on the
input shaft, the cooling fan blowing dusty air and oil
on the transmission will quickly pack the cooling
fins with oily dirt. If this condition occurs, replace
the seal immediately to avoid overheating and dam-
aging the transmission. The input shaft assembly
and seal are easily replaced without removing the
transmission from the machine.
An additional procedure in maintaining transmission
cooling is to inspect the cooling fans. Replace the
fan(s) if blades are missing or damaged.
Hydrostatic Transmission Cooling Fins
CHECKING/SERVICING
Security of Air Filtration Components
NOTE: The following inspection is only an exter-
nal inspection and should be done without “dis-
turbing” the filtration components.
On a daily basis, visually inspect the external condi-
tion of the complete air cleaner system. The follow-
ing items should be inspected:
1. Check the security of the engine air cleaner
cover and inspect it for damage and make sure
it seals properly with the engine baseplate. Im-
proper sealing may be caused by a bent base-
plate.
2. Check the Donaldson Radialseal™ air cleaner
canister for damage. Make sure the cover is in
place and the cover latches are secure - do not
run the engine without the air cleaner cover in
place and secure.
3. Inspect both air intake hoses for cracks, nicks,
cuts, etc., and check the hose clamps for tight-
ness.
Battery
NOTE: For initial battery service during setup, re-
fer to Battery Service in Assembly Instructions.
Electrolyte Level
The battery electrolyte level should be checked af-
ter every 25 hours of operation. To check electro-
lyte level:
1. Remove battery cell filler caps.
2. Check the electrolyte level. If the level is below
the bottom of the vent well, fill with drinking wa-
ter to the bottom of the vent wells [1/4 to 1/2 in.
(6 to 13 mm) above the plates].
Cooling Fins
Cooling Fan
DANGER
To prevent accidental starting of the en-
gine when servicing or adjusting the ma-
chine, remove the key from the ignition
switch and disconnect the spark plug
wires.