Raypak 105B Swimming Pool Heater User Manual


 
SECTION 4 / SERVICING INSTRUCTIONS
GENERAL LOCATION OF CONTROLS
18
CONTROLS/ADJUSTMENTS/
REPLACEMENTS
TEMPERATURE CONTROLS
The water temperature is controlled by the heater
thermostat on the upper front panel of the heater. The
control center contains an On/Off toggle switch and a
thermostat. The switch functions as a means for turning
the heater on or off.
The thermostat is fitted with a means of limiting the
upper temperature limit below the maximum level. The
knob stop adjustment ring illustrated below is adjust-
able by loosening the set screw, rotating the knobstop
ring to the desired location and retightening the set
screw.
Typical
Comfortable
Spa
Temperature
Range
Typical
Comfortable
Pool
Temperature
Range
Knobstop Ring Set Screw
PRESSURE SWITCH
The pressure switch, or heater actuator, insures
that the heater operates only when the filter pump is in
operation. It is factory set at 1.75 PSI for deck level
installations. When the heater is located below the level
of the spa or pool, it may be necessary to reset the
pressure switch to compensate for the no-flow static
head. If it is necessary to reset the pressure switch, we
recommend the following procedure: see next page
please.
HIGH LIMITS
BYPASS
VALVE
THERMAL
FUSE
TRANSFORMER
IGNITION CONTROL (IID)
BURNERS & PILOT
GAS VALVE
PRESSURE
SWITCH
MANUAL
SWITCH
MANUAL
THERMOSTAT
Fig# 9252