Proper location of the generator set is important to
insure safe and reliable operation and can aid in the
installation of the generator. When selecting a site for the
generator, first ensure that the pad is outdoors in a well
ventilated area to allow for proper cooling and proper
removal of deadly exhaust fumes created during
operation. Consider the direction of the engine exhaust
exiting the cabinet and orient the generator on the site
with the exhaust away from any windows, doors,
ventilation intakes or other openings that can allow
engine exhaust fumes to collect in a confined area. In
addition, take into account any prevailing winds or other
air currents that could carry engine exhaust fumes in
unintended directions.
For minimum installation costs, plan to locate the
generator outside at a position adjacent to the electrical
service distribution panel and close to the intended fuel
supply.
To assure adequate cooling air and access for
maintenance, plan to locate the generator so that a
minimum of three (3) feet of clear, unobstructed space is
available on all sides of the cabinet, including above the
lid. If landscaping is used to mask the generator from
view or further control sound, leave enough room so that
the mature plants still allow three feet of clear space
around all sides. If necessary, place a screen style fence
around the site to prevent grass, leaves or other
combustible debris from gathering around the generator,
creating a fire risk.
GG
GG
EE
EE
NN
NN
EE
EE
RR
RR
AA
AA
TT
TT
OO
OO
RR
RR
LL
LL
OO
OO
CC
CC
AA
AA
TT
TT
II
II
OO
OO
NN
NN
CCAAUUTTIIOONN
Covering or restricting the air passages on the
generator will cause the unit to overheat and
may create a fire hazard. Do not allow snow or
leaves to cover enclosure openings.
Leave a three foot open area around all sides of
the unit. Do not plant trees or plants which may
grow within three feet of the unit.
Unit should be located to prevent combustible
material from accumulating against the
generator set.
The generator MUST be installed outdoors.
DDAANNGGEERR
Generator exhaust air contains carbon
monoxide, a deadly odorless, colorless and
tasteless gas. Breathing carbon monoxide
causes severe nausea, fainting or death. Install
the generator outdoors only. Do not use
exhaust air to heat a room. Do not allow exhaust
air to enter a building through windows, doors,
air intakes or other means. Avoid breathing
exhaust air while installing, operating or
servicing the generator. The engine exhaust
from this product contains chemicals known to
the State of California to cause cancer, birth
defects, or other reproductive harm.
Considerations for proper rooftop placement
and weight distribution must be designed by a
licensed engineer or architect.
WWAARRNNIINNGG
For fire safety, the generator must be installed
and maintained properly. Installation always
must comply with applicable codes, standards,
laws and regulations. Adhere strictly to local,
state and national electrical and building codes.
Comply with regulations established by the
Occupational Safety and Health Administration
(OSHA) and National Electrical Code (NEC).
This generator is designed to be installed
outside only. Never install this unit inside any
room, enclosure, or basement. The generator
needs adequate cooling and ventilation for
continued proper and safe operation.
The exhaust from this product is extremely hot
and remains hot after shutdown. High grass,
weeds, brush, leaves or other combustible
materials, must remain clear of the exhaust.
Such materials may ignite and burn from the
heat of the exhaust system.