Backwash Mode
When the Filter mode has detected that the differential pressure is at the “Clean Filter Pressure” the filter
must be cleaned. You need to stop IntelliFlo either by pressing the Backwash button or “Start/Stop” button.
IntelliFlo must now be run for a preset cycle time with a preset flow. The flow is adjustable to accommodate
the specific filter backwash flow requirement. After the backwash cycle, a rinse cycle, with preset duration
time will be executed. When the two cycles have been completed or if the Start/Stop button is pressed to
stop the process, the filter status will be recalculated and the zero-pressure measured when Filter mode is
operated again.
Backwash is a essential mode for cleaning as well as maintaining the % Clean Filter menu
Backwash mode tells the computer to recalculate the clean filter pressure and start a new cycle
Backwash button doubles for Rinse in operation
When using cartridge filters the backwash cycle must be performed when cleaning or replacing
filters. This helps the computer reset its 0 head pressure level
If you are charging a DE system, charge the system first during a normal running cycle. After the
filter is charged, run the pump in backwash mode with the filter valve in the filter position to reset the
% clean filter status. Then run the pump in filter mode.
Note: IntelliFlo will ramp up to full speed if necessary to achieve the commanded flow. Be sure that
the system can withstand the resultant pressures.
Backwash menu
To access the Backwash menu:
1. Ensure that the green power LED is on and the pump is stopped.
2. Press the Menu button. Press the Up or Down arrows to select the “Backwash”
menu.
3. To set the backwash flow parameter: Press the Select button, the “Backwash
Flow” parameter is displayed. To edit the backwash flow parameter, see step 6.
This parameter can be set from 15 GPM to 130 GPM. The default setting is 60
GPM. This parameter sets the preset flow for both backwash and rinse modes.
4. To set the backwash cycle time parameter: Press the Up or Down arrows to
select the “Backwash Duration” menu. To edit this setting, see step 6.
This parameter can be set from 1 to 60 minutes. The default setting is 5 minutes.
This setting is the cycle time for the backwash mode.
5. To set the backwash rinse time parameter: Press the Up or Down arrows to
select the “Rinse Duration” menu. To edit this setting, see step 6.
This parameter can be set from 1 to 60 minutes. The default setting is 1 minutes. This setting is the
cycle time for the rinse mode.
6. To change the value, press the Left and Right arrows to select which digit to modify, then use the Up
and Down arrows to change the selected digit.
7. When you are done, press the Enter button to save the changes. To cancel any changes, press the
Escape button to exit edit mode without saving.