Pentair IntelliComm Swimming Pool Pump User Manual


 
13
IntelliFlo Installation and User’s Guide
Pool Data Mode
Use the Pool Data menu to configure IntelliFlo for the pool and spa system. From this menu you can set an
address for the IntelliFlo pump when connected to an IntelliTouch system, set the volume of pool water, in
1000’s of gallons (kgal) and estimated pool water temperature.
To access the Pool Data menu:
1. Ensure that the green power LED is on and the pump is stopped.
2. Press the Menu button.
3. Press the Up and Down arrow buttons to scroll through the menu items. Press the
Select button to access the “Pool Data” menu.
4. To enter the pump volume (pool size): Press the Select button to access “Pool
Volume” setting. To enter the pool volume setting, see step 7.
The “Pool Volume” value is expressed as 1000’s of gallons (Kgal). Enter from 1 to
1000 Kgal for the pool volume. The volume number can be a close estimate, although
the more accurate the better the turns will be done when employing filter mode. Filter
mode uses this value in coordination with the parameters from Filter mode to sustain
turn rates, flows, and times.
5. To set the water temperature: Use the Up and Down arrows to select “Water
Temperature”. To set the water temperature, see step 7.
Enter the current water temperature from 68° F - 104° F (Default 75° F.) The “Water
Temp” is only for the accuracy of the flow sensor. Temperature accuracy is not
critical, just enter an approximate temperature. When the IntelliFlo is connected to an
IntelliTouch system, water and air temperature information is provided by the system
sensors. The flow reading on the IntelliFlo is –0 / +2 GPM. The closer the
temperature to the actual temperature, the more accurate the flow reading on the
IntelliFlo control panel LCD will be while it’s running.
6. To enter the pump address: Press the Select button to access the “Pump Address”
setting. To enter the IntelliFlo pump address, see step 7.
This setting is only used if IntelliFlo is connected to the IntelliTouch system. The
“Pump Address” identifies the pump number (1-16) that is displayed on the
IntelliTouch control panel for programming. For example, if there are multiple IntelliFlo
pumps, pump address 1 can be name as “Spa Pump,” in the IntelliTouch control panel.
The IntelliTouch system can address and control up to eight different pumps using the
RS-485 COM port connection. Note: IntelliFlo pumps cannot be connected in
series with other pumps. Check valves must be used when an IntelliFlo is used in
parallel with other pumps.
7. Press the Select button to change the current setting.
8. To enter a new setting, press the Left and Right arrows to select which digit to modify,
then use the Up and Down arrows to change the selected digit.
9. When you are done, press the Enter button to save the changes. To cancel any
changes, press the Escape button to exit edit mode without saving.
Filter Vacuum
Back
Wash
Manual
Enter
Select
Reset
Feature
2
Feature
1
Menu
Escape
On
War n.
Alarm
IntelliFlo
®
MENU
12:15
Pool Data
Start
Stop
Filter Vacuum
Back
Wash
Manual
Enter
Select
Start
Stop
Reset
Feature
2
Feature
1
Menu
Escape
On
Warn.
Alarm
IntelliFlo
®
Pool Data
Pool Data
12:01
12:01
Pump Address
Pump Address
1
Filter Vacuum
Back
Wash
Manual
Enter
Select
Start
Stop
Reset
Feature
2
Feature
1
Menu
Escape
On
Warn.
Alarm
IntelliFlo
®
Pool Data
Pool Data
12:15
12:15
Pool Volume
Pool Volume
31.kGAL
31.kGAL
Filter Vacuum
Back
Wash
Manual
Enter
Select
Start
Stop
Reset
Feature
2
Feature
1
Menu
Escape
On
Warn.
Alarm
IntelliFlo
®
Pool Data
Pool Data
12:15
12:15
Water Temperature
Water Temperature
75.F