Pentair IntelliComm Swimming Pool Pump User Manual


 
32
IntelliFlo Installation and User’s Guide
Connecting IntelliFlo to IntelliTouch (Continued)
6. Strip back the cable conductors ¼”. Insert the wires into the either of the COM PORTS (J7 and
J8) screw terminals located on the left side of the Personality board. Secure the wires with the
screws. For wiring details, refer to the pin configuration shown below. Note: Multiple wires may be
inserted into a single screw terminal.
Pin Configuration for IntelliFlo to IntelliTouch:
• IntelliFlo: Connect pin 6 (green) to IntelliTouch screw terminal pin 2 (green)
• IntelliFlo: Connect pin 7 (yellow) to IntelliTouch screw terminal pin 3 (yellow)
7. Close the IntelliTouch control panel and secure it with the two access screws.
8. Install the high voltage panel cover and secure it with the two retaining screws.
9. Close the load center front door and secure with the two latches.
10. Switch power on to the IntelliTouch load center.
Pin 6
(Green)
Pin 7 (Yellow)
IntelliFlo cable pin configuration
Pin configuration
IntelliTouch
COM PORT (J7/J8)
screw terminal
hcuoTilletnI
lanimretwercs
rotcennoc
olFilletnI
)elbaceriw-2(
)NRG(2)6niP(NEERG
)LEY(3)7niP(WOLLEY
BLK
GRN
YEL
RED
IntelliTouch Personality
board COM PORT
(J7/J8)