MAINTENANCE
F-N-R CONTROL ADJUSTMENT
Control (cable) adjustment for the F-N-R should not normally
be necessary; however, some adjustment can be made on
each of the rod end adjustment nuts. See Figure 64.
Figure 64. F-N-R Control Adjustment
1
3
2
1
2
3
4
1. Adjustment Nut
2. Rod End
3. Push-Pull Cable
4. Neutral Safety Switch
HYDRAULIC SYSTEM MAINTENANCE
Many hydraulic problems are a result of low fluid levels.
Before checking any other possibilities, make sure the
hydraulic fluid level is correct. See Figure 66 for hydraulic
components. Hydraulic problems could be a result of the
following:
1. Incorrect hydraulic fluid level.
2. Plugged hydraulic oil filter
3. Loose or leaking fittings.
4. Ruptured/damaged hydraulic lines.
5. Faulty hydraulic pump.
Hydraulic Oil System
1. Check hydraulic oil level daily.
2. When checking or adding hydraulic oil, place the
machine so the saw frame is level to get an accurate
reading.
3. Hydraulic oil should be 1/2" to 1" in the Oil Reserve
when cold.
4. If hydraulic oil level is low add oil to 1/2" to 1".
5. Use 15W-40 premium grade engine oil.
6. Change oil and filter annually. See Figure 65.
DANGER — Hydraulic Leaks
NEVER
use your hand to find hydraulic
leaks. Use a piece of wood or cardboard.
Hydraulic fluid injected into the skin must
be treated by a knowledgable physician
immediately or severe injury or death can
occur.
Figure 65. Oil Reserve Fill Line