Invacare IH6300 Hot Tub User Manual


 
SECTION 5—MAINTENANCE
Part No 1096926 29 Supine Bath Tub
15. Adjusttheinjectorbyperformingoneofthefollowing:
BottomofFloatingBallReadsGreaterThan35‐Lessdisinfectantneedstobeaddedtothemixture.
Loosenthescrewontheinjectortodrawlessdisinfectantintothesolution.
BottomofFloatingBallReadsLessThan35‐Moredisinfectantneedstobe
addedtothemixture.
Tightenthescrewontheinjectortodrawmoredisinfectantintothesolution.
16. Whenthebottomofthefloatingballisnear35,turntheblackadjustmentknobontheflowmeteruntil
thebottomofthefloatingballisat35.
17. Placethebucket/pailunderthe
burpfittingtocollectthedisinfectant.Useafunnelifnecessary.
18. Notethenumberofouncesinthegraduatedp lasticbottle.
19. Letthebucket/pailfilltoonegallon.
20. Turnthedisinfectantvalvetotheoffposition.
21. Removethedisinfectantdrawtubefromtheplasticbottle.
22. Examinetheamountofdisinfectantremaininginthe
plasticbottle.
23. SubtracttheamountofdisinfectantremainingfromtheamountnotedinSTEP18.
24. Performoneofthefollowing:
•Approximately½ounceofdisinfectanthasbeenused‐ProceedtoSTEP23.
•Muchmoreormuchlessthan½ounceofdisinfectanthasbeenused‐repeatSTEPS118.
25. Positionthe
disinfectantdrawtubeintothedisinfectantsolution.
26. Disinfectthetub.RefertoDisinfectingtheTubUsingtheClosedLoopSystem
onpage 12.
FIGURE 5.2 Calibrating the Disinfectant Flowmeter
Disinfectant Cabinet
Disinfectant
On/Off Valve
Ball
Flow meter
Adjustment Knob
Disinfectant
Siphon Tube
Screw
Injector
Disinfectant Siphon Tube