Husqvarna 260 ACX Lawn Mower User Manual


 
English - 59
7. GARDEN EXAMPLE
Area: 3000 m
2
. There are several islands. No
guide wire is necessary. The mower’s default
settings do not need to be changed.
Timer: Operating time of 15 hours per day.
Exit angles: 90°- 270°.
Search method: Irregular.
Delay: Guide 1 4 minutes, Guide 2 4 minutes
and boundary wire 11 minutes.
Corridor width: 10
Area: 1000 m
2
. There is one small island.
Guide wire recommended through the
passage.
Timer: Operating time of 5 hours per day.
Exit angles: 70° - 190°.
Follow loop out: Direction Guide 1, Distance
20 m and Proportion 25 %.
Search method: Irregular, Follow guide wire
in and Follow boundary wire in.
Delay: Guide 1 4 minutes, Guide 2 4 minutes
and boundary wire 11 minutes.
Corridor width: Guide 1 7, boundary wire
20.
Area: 4000 m
2
. Two guide wires are
recommended.
Timer: Operating time of 24 hours per day.
Exit angles: 90°-270°.
Follow loop out: Area 1; Direction Guide 1,
Distance 30 m and Proportion 15 %. Area 2;
Direction Guide 2, Distance 30 m and
Proportion 30 %.
Search method: Irregular, Follow guide wire
in and Follow boundary wire in.
Delay: Guide 1 2 minutes, Guide 2 2 minutes
and boundary wire 11 minutes.
Corridor width: Guide 1 4, Guide 2 4 and
boundary wire 6.
Proposals for installation and settings