Hunter Fan 41457-01 Outdoor Ceiling Fan User Manual


 
33
41457-01 7/2000
®
TROUBLESHOOTING
Nothing happens; fan does not move.
Without Remote (refer to page 35 for
troubleshooting With Remote).
Noisy operation.
1. Power turned off, fuse blown, or
circuit breaker tripped.
2. Loose wire connections or wrong
connections.
3. Motor reversing switch not en-
gaged.
4. Pull chain switch not “on.”
5. Shipping bumpers still in place.
1. Blade brackets screwed loosely to
motor.
2. Blade screwed loosely to blade iron.
3. Blade cracked.
PROBLEM PROBABLE CAUSE SOLUTION
1. Turn power on, replace fuse, or re-
set breaker.
2a.Loosen canopy, check all connections
according to STEP 7 - WIRING THE
FAN (turn power off before
checking).
2b.Check the plug connection in the
switch housing according to STEP
10 - ATTACHING THE SWITCH
HOUSING.
3. Push switch firmly up or down.
4. Pull switch chain.
5. Remove shipping bumpers.
1. Tighten screws until snug.
2. Tighten screws until snug.
3. Replace all blades.
continued