AquaFit™ Dual-Temp (Spa-Side)
Symptom Problem Corrective Action
“OH” on LED Digital Display
Window
High Temperature Condition:
Do not enter spa water. The water
temperature is above acceptable
limits. The water temperature has
reached 110°F (43.3°C.). The
system will shut down.
Remove the cover and allow the
water to cool.
Reset the power to the spa by
resetting the GFCI breaker.
No further action is required unless
the water temperature fails to return
to acceptable levels – in which case,
call your dealer for service.
3 Flashing Lights AND
“OH” on LED Digital Display
Window
High Limit Condition:
Do not enter spa water. The water
temperature is above acceptable
limits. The water temperature has
reached 118°F (47.8°C.). The
system will shut down.
Call your dealer for service.
3 Flashing Lights
System Error:
1. Check the water level
2. Clean the filters.
3. If the problem persists, reset the
power to the spa by resetting
the GFCI breaker.
If the error is not resolved after
resetting the spa, call your dealer for
service.
Temperature Probe Failure:
If the LED Digital Display shows
32°F (0°C) or 136°F (57°C), you
have an open temperature sensor.
The heater is deactivated.
Call the dealer for service.