Dimension One Spas Aquatic Fitness System Hot Tub User Manual


 
Dimension One Spas - Aquatic Fitness System - Owner’s Manual
27
Self-Diagnostic System
“Pool-Side” Control Panel
If one of the following messages appears in the Pool Side control panel, take the corrective action
described below.
Symptom Problem Corrective Action
Non-functional
High Temperature Sensor:
Open high temperature sensor. Heater is
deactivated.
Call your dealer for service.
Non-functional temperature sensor:
Open temperature sensor. Heater is
deactivated.
Call your dealer for service.
Water Flow Problem:
Pressure switch is not closed when the
pump is activated. Heater is deactivated.
Proper flow of water is inhibited or pressure
switch has malfunctioned. Check for proper
water level, ensure pump is primed and/or
check for clogged filter. Pressure switch
may need to be adjusted.
Call the dealer for service.
Pressure switch problem:
Pressure switch is closed, while pump is
deactivated. Pressure switch may need to
be adjusted.
Call your dealer for service.
Cool condition:
If the water temperature drops 20°F
(11°C) below the set temperature, the low
speed pump and the heater will activate to
bring the temperature within 15°F (8°C) of
the set temperature.
No corrective action is required.
Freeze condition:
Do not enter the spa water. A potential
freeze condition has been detected (55°F /
12°C.)
No action is required.
The low speed pump will be activated
along with the heater. The spa will
automatically heat, until the spa is out of
danger (65°F / 18.3°C.)