Clarke S20E Swimming Pool Vacuum User Manual


 
CLARKE TECHNOLOGY Operator's Manual -Encore S20E Page -19-
2. Check and clean the filter screen in the solution hose.
To clean the screen, follow this procedure: (See figures
11 and 12 page 18)
a. Turn the connector to the left.
b. Remove and clean the filter screen.
c. Install the filter screen in the hose. Turn the
connector to the right to connect the hose.
3. Use a grease gun to lubricate the caster. See figure
6.
4. Check the squeegee and the scrub brush or the pad
driver for damage.
5. Check the squeegee and the vacuum hose for damage,
leaks and obstructions.
Maintenance For The Squeegee
To remove the squeegee, follow this procedure:
1. Remove the squeegee assembly by loosening the two
knobs that attach the squeegee to the machine. Pull the
squeegee assembly off. See figure 7.
2. Inspect the squeegee blade.
3. If the blade is worn, turn the blade so that a new edge
is in the wiping position.
4. Reinstall squeegee assembly on the machine.
How To Adjust The Squeegee
The following adjustments are set at the factory, however
they may require slight adjustment.
Adjusting Squeegee Pressure:
To adjust the pressure, refer to Figure 8. Proper
adjustment will produce a uniform flare along the rear
blade when the machine is moved forward. To increase
pressure, loosen bolt and slide squeegee mount down.
To decrease the pressure, loosen the bolt and slide
squeegee mount up.
MAINTENANCE
Figure 6
Figure 7
Figure 8
Figure 7
Figure 8