Clarke S20E Swimming Pool Vacuum User Manual


 
Page -14- CLARKE TECHNOLOGY Operator's Manual -Encore S20E
There is no solution flow.
The solution flow does not stop.
The machine does not remove all the
water from the floor.
Open the solution valve.
Remove the obstruction from the hose and the
filter.
Repair or replace the valve and the electric
wiring.
Fill the solution tank.
Check solution module
Close or Clean the solution valve.
Repair or replace the valve and the wiring.
Clean the solution valve.
Replace the seat and washer.
Check solution module.
Lower the squeegee.
(See Figure 11, page 23)
Drain the tank.
Clean the screen filter.
Remove the obstruction or repair the damage.
Check for tripped breaker. Have an autho-
rized service person make repairs.
Check and connect hose.
Turn or replace the squeegee blade.
Correctly install the squeegee blade.
Adjust the pressure of the squeegee.
Replace the gaskets.
Rotate lid 180° and replace.
PROBLEM CAUSE ACTION
The solution valve is closed.
There is an obstruction in the solution hose
or filter.
The solution valve or electric wiring is
damaged.
The solution tank is empty.
The solution module is damaged.
The solution valve is open or dirty.
The solution valve or wiring is damaged.
The solution valve is dirty
There is a damaged seat and washer in the
solution valve.
The solution module is damaged.
The squeegee is up
The squeegee tilt is not correct.
The vacuum tank is full.
The screen filter is dirty.
There is an obstruction or damage in the
squeegee, squeegee hose or standpipe.
The vacuum motor is not running.
The squeegee hose is disconnected, or
damaged
The squeegee blade is damaged, worn, or
incorrectly installed.
The squeegee pressure is not correctly
adjusted.
The gaskets on the cover of the recovery
tank are damaged.
The recovery tank lid is on wrong.
HOW TO CORRECT PROBLEMS IN THE MACHINE