Agilent Technologies E8663B Portable Generator User Manual


 
Agilent N518xA, E8663B, E44x8C, and E82x7D Signal Generators Programming Guide 315
Creating and Downloading User-Data Files
Pattern RAM (PRAM) Data Downloads (E4438C and E8267D)
Command Syntax
:MEMory:DATA:PRAM:FILE:LIST <"file_name">,<uint8>[,<uint8>,<...>]
uint8 The decimal equivalent of an unsigned 8-bit integer value. For a list of usable
decimal values and their meaning with respect to the generated signal, see Table
8-6 on page 312.
Command Syntax Example
The following example, when executed, creates a new file in volatile (waveform) memory with the
following attributes:
creates a file named new_file
outputs a single pulse at the EVENT 1 connector
bursts the data pattern 1100 seven times over 28 bytes
transmits 32 nonbursted bytes
resets the data pattern so it starts again
:MEMory:DATA:PRAM:FILE:LIST <"new_file">,85,21,20,20,21,21,20,20,21,21,20,20,21,21,
20,20,21,21,20,20,21,21,20,20,21,21,20,20,16,16,16,16,16,16,16,16,16,16,16,16,16,16,
16,16,16,16,16,16,16,16,16,16,16,16,16,16,16,16,16,144
The following list defines the meaning of the different bytes seen in the command line:
SCPI Command for a Block Data Download
The IEEE standard 488.2-1992 section 7.7.6 defines block data. The signal generator is able to
download block data significantly faster than list formatted data (see page 314), because it does not
have to parse the data. When creating the data, remember that the signal generator requires a
minimum of 60 bytes. For more information on file size limits, see “PRAM File Size” on page 313.
Command Syntax
:MEMory:DATA:PRAM:FILE:BLOCk <"file_name">,<blockdata>
The following sections explain how to format the SCPI command for downloading block data:
Command Syntax Example
Command Syntax in a Program Routine
Command Syntax Example
This example conceptually describes how to format a block data download command (#ABC represents
the block data):
85 Send a pulse to the EVENT 1 output, and burst the signal with a data bit of 1.
21 Burst the signal with a data bit of 1.
20 Burst the signal with a data bit of 0.
16 Do not burst the signal (RF output off), and set the data bit to 0.
144 Reset the data pattern, do not burst the signal (RF output off), and set the data bit to 0.