Agilent Technologies E4438C Portable Generator User Manual


 
37
501 1 GHz frequency range
502 2 GHz frequency range
503 3 GHz frequency range
504 4 GHz frequency range
506 6 GHz frequency range [requires option UNJ, includes mechanical attenuator]
UNB High output power with mechanical attenuator
[included with 506]
UNJ Enhanced phase noise performance
[includes 1E5]
1E5 High-stability time base
1EM Moves all front panel connectors to rear
003
2
ESG digital output connectivity with N5102A Baseband Studio digital
interface module
004
2
ESG digital input connectivity with N5102A Baseband Studio digital
interface module
601 Internal baseband generator with 8 MSa and digital bus capability
[40 MB] of memory
602 Internal baseband generator with 64 MSa and digital bus capability
[320 MB] of memory
005
3
6 GB internal hard drive
UN7 Internal bit-error-rate analyzer
300 GSM/EDGE base station loopback BERT
3GPP W-CDMA FDD personality
cdma2000 and IS-95-A personality
TDMA personality (GSM, EDGE, GPRS, EGPRS, NADC, PDC, PHS, DECT, TETRA)
Calibrated noise (AWGN) personality
GPS personality
Signal Studio for 1xEV-DO/1xEVDO Rev A
Signal Studio for 1xEV-DV and cdma2000
Signal Studio for 802.11 WLAN
Signal Studio for Bluetooth
Signal Studio for enhanced multitone
Signal Studio for HSDPA over W-CDMA
Signal Studio for TD-SCDMA
Signal Studio for Noise Power Ratio (NPR)
Signal Studio for S-DMB
Signal Studio for T-DMB
Signal Studio for pulse building
Signal Studio for jitter injection
Signal Studio toolkit
Signal Studio for 802.16-2004 (WiMAX)
Signal Studio for 802.16 OFDMA
Signal Studio for DVB
N5102A Baseband Studio digital signal interface module
N5110B Baseband Studio for waveform capture and playback
5
N5115A Baseband Studio for fading
5
N5101A Baseband Studio PCI card
5
1CP Rack mount kit with handles
1CN Front handle kit
Ordering Information
1
1. All options should be ordered using E4438C-xxx, where the xxx represents the option number. For more information, please refer to the
configuration guide publication number 5988-4085EN.
2. Requires either Option 601 or 602 (baseband generator) to function.
3. Requires Option 001, 002, 601, or 602.
4. For details visit www.agilent.com/find/basebandstudio
5. Baseband Studio for waveform capture and playback and for fading both require a PC equipped with the Agilent N5101A Baseband Studio PCI card.
The PCI card is not functional as a stand-alone product.
6. For the latest information visit www.agilent.com/find/signalcreation
Frequency options
Performance enhancement options
Signal creation software
3, 6
Baseband Studio products
4
System accessories