bitC. In in-position (INP)
The status changes to INP=1 when position droop exists within the in-position area set by
parameter SP024 (INP) regardless of serve ON or OFF.
bitD. In current limit (LMT)
It indicates that the drive unit is in current limit at LMT=1.
bitE. In absolute position data loss (AER)
It indicates that the drive unit is in absolute position data loss at AER=1.
bitF. In warning (WRN)
It indicates that drive unit is in some warning state at WRN=1.