A SERVICE OF

logo

7. SERVO PARAMETERS
7.4 MDS-R-Vx
II - 202
No. Items Details Setting range
F E D C B A 9 8
zup dis
7 6 5 4 3 2 1 0
nfd2 nf3 nfd1
2233 SV033
SSF2
Servo
function
selection 2
bit Meaning when "0" is set Meaning when "1" is set
0
1 Set the filter depth for Notch filter 1 (SV038).
2 nfd1 Value 000 001 010 011 100 101 110 111
3
Depth
(dB)
Infntly
deep
-18.1 -12.0 -8.5 -6.0 -4.1 -2.5 -1.2
DeepÅ Æ Shallow
4 nf3 Notch filter 3 stop Notch filter 3 start (1125Hz)
5 Set the operation frequency of Notch filter 2 (SV046).
6 nfd2 Value 000 001 010 011 100 101 110 111
7
Depth
(dB)
Infntly
deep
-18.1 -12.0 -8.5 -6.0 -4.1 -2.5 -1.2
DeepÅ Æ Shallow
8
9
A
B
dis
Select the digital signal input.
00: DI not used
01: Contactor B contact input
10: Reserved
11: Reserved
C
D
E zup Vertical axis pull up control stop Vertical axis pull up control start
F
(Note) Set to "0" for bits with no particular description.