5. BASE SPECIFICATIONS PARAMETERS
II - 45
# Items Details Setting range (unit)
1155 DOOR_m Signal input
device 1 for
door
interlock II
Set up a fixed device number (X??) for door interlock
II signal input.
A device number from X01 to XFF can be set up.
Device number 000 is invalid. Set up device number
100 when using no fixed device number for door
interlock II signal input.
Related parameter: #1154 pdoor Door interlock II
(for each system)
000 to 100
(Hexadecimal)
1156 DOOR_s Device
number 2
for door
interlock II
signal input
Set up a fixed device number (X??) for door interlock
II signal input. (Set up the same value as that of
#1155.)
Related parameter: #1154 pdoor Door interlock II
(for each system)
000 to 100
(Hexadecimal)
1157 F0atrn F0
automatic
running
Not used
1158 F0atno F0
automatic
running
program
Not used
1165 p_trans Not used.
1166 fixpro Fixed cycle
editing
Select whether to use the edit, program list and data
input/output functions for the fixed cycles, machine
manufacturer macro programs or general programs.
0: General programs can be edited, etc.
1: The fixed cycles can be edited, etc.
Password No.: The machine manufacturer macro
programs can be edited, etc.
0 to 99999999
1167 e2rom Not used.
1168 test Simulation
test
Specify the test mode for the control unit.
The test mode does not use reference point return‚
and tests with a hypothetical zero point return
completed state. This is limited to test operation of the
control unit itself‚ and must not be used when
connected to the machine.
0: Normal
operation mode
1: Test mode