5. BASE SPECIFICATIONS PARAMETERS
II - 22
5. BASE SPECIFICATIONS PARAMETERS
After setting up the parameter (PR) listed in the table, turn OFF the NC power. To validate the parameter,
turn ON the power again.
(SETUP PARAM 1. 1/16)
# Items Details Setting range (unit)
1001
(PR)
SYS_ON System
validation
setup
Specify the existence of the NC axis and PLC axis
with 1 or 0.
0: Not used
1: Used
1002
(PR)
axisno Number of
axes
Set the number of NC axes and PLC axes.
With E68, specify 4 as the maximum value for the
NC axis and 2 as that for the PLC axis so that the
total of those values is 6 or less.
With E60, specify 3 as the maximum value for the
NC axis and 2 as that for the PLC axis so that the
total of those values is 5 or less.
0 to 4
1003
(PR)
iunit Input setup
unit
Specify the input setting unit for the NC axis and
PLC axis. The parameter units will follow this.
B: 1
µ
m
C: 0.1
µ
m
1013 axname Axis name Specify each axis’ name address with an alphabetic
character.
Use the characters X‚ Y‚ Z‚ U‚ V‚ W‚ A‚ B or C.
Do not specify the same address.
The PLC address does not need to be set. (The axis
name is displayed as 1 and 2.)
Axis addresses such as
X, Y, Z, U, V, W, A, B,
and C
1014 incax Increment
command
axis name
When specifying the program movement rate’s
absolute or incremental method with an address‚
specify the incremental command axis name
address with an alphabetic character.
The address that can be used is the same as #1013
axname.
Specify an address that is different from that #1013.
Setting is not required if absolute/incremental
specification with addresses is not performed
(#1076 Abslnc = 0).
1015
(PR)
cunit Command
unit
Specify the minimum unit of the program movement
amount.
cunit Movement amount for movement command 1
0: #1003 iunit is followed.
1: 0.0001mm (0.1µm)
10: 0.001mm ( 1 µm)
If there is a decimal point in the movement
command‚ the decimal point position will be handled
as 1mm regardless of this setting.
0 #1003 iunit
1
0.1
µ
m
10
1
µ
m
1016
(PR)
iout Inch output Specify whether the machine system (ball screw
pitch‚ position detection unit) is an inch unit system
or metric unit system.
0: Metric unit
system
1: Inch unit system