SPA START-UP cont...
TESTING THE GFCI BREAKER cont...
NOTE: When power is turned on, your spa is automatically pro-
grammed to start circulating water through the circulation pump.
Each pump and/or blower will come on consecutively for approxi-
mately 1 minute to automatically purge the system. Adjust your
temperature by pressing the up button on your touch pad until the
desired temperature is displayed. This setting will allow your spa
to heat to the set temperature.
CAUTION: If water is not noticeably coming from your spa jets dur-
ing the automatic purge, turn on the high speed pump. If water
is still not coming from the jets, the pump needs to be manually
primed, following the steps below.
PRIMING THE PUMP
1) Turn off power at electrical service panel.
2) Locate and loosen one of the pump plugs on each pump by turning it
counterclockwise one half of one turn.
3) Allow air to escape from ttings. When a steady stream of water ows
from the pump plug, close it by turning it clockwise until tight.
4) Turn on power at electrical service panel.
5) Check once more to make sure that water is owing from the jets dur-
ing auto purge. If so, continue. If no water is coming from your spa jets,
please call your Artesian dealer for further assistance.
WATER PREPARATION
NOTE: Before putting your new spa into operation, understand
that preparing your new water is an important part of maintenance.
Failure to properly prepare your water can result in substantially
decreasing the life of the components and may void your warranty
in severe cases. Your Artesian dealer should have a start-up and
maintenance kit available for you when you receive your spa.
20