Vita Spa Portable Spa Hot Tub User Manual


 
PAGE 11
1. Push the TEST button on the GFCI. The
RESET button will trip out, the
GFCI
indicator window will turn white and the top
side digital control LED display will go out. If
this does not happen, DO NOT USE THE
VOYAGER. CALL DM INDUSTRIES LTD'S
SERVICE CENTER FOR ASSISTANCE.
2. If the GFCI tests properly, firmly push the
RESET button back into place. The GFCI
indicator window will turn red and the top side
digital control LED display will come back on.
If this does not happen, DO NOT USE THE
VOYAGER. CALL DM INDUSTRIES LTD'S
SERVICE CENTER FOR ASSISTANCE.
3. If the GFCI trips by itself at any time, firmly
press the RESET button back into place and
perform the above tests. If this happens more
than once, DO NOT USE THE VOYAGER.
CALL DM INDUSTRIES LTD'S SERVICE
CENTER FOR ASSISTANCE.
Once the Voyager is properly powered, the digital
control will start the pump after a few seconds
and water should start flowing through the jets. If
no water is coming through, unplug the
GFCI and
repeat the priming procedure or see the trouble
shooting chart on page 18.
Your Voyager spa has been designed to be simple
to operate and maintain. It is equipped with state-of-
the art digital control with LED readout (see
previous page) to show temperature and time. The
digital control has been factory programmed for
your convenience. Once properly connected, the
filtration pump and heater will automatically come
on and heat the spa to 102
A. Displaying Time or Water Temperature.
Pressing the "PROG" button will switch the
display between time and water temperature.
B. Setting Temperature and Time
1. Press and hold down the "PROG" button for 5
seconds until the display starts flashing. Note
that the display will be flashing during this
procedure.
2. Press the "UP" or "DOWN" arrow to select the
desired temperature.
3. Press the "PROG" button to show the "Hours".
4. Press the "UP" or "DOWN" arrow to select the
current hour. Note the AM and PM indicators.
5. Press the "PROG" button to show the Minutes.
6. Press the "UP" or "DOWN" arrow to select the
current minute.
7. Press "PROG" button to exit the programming
mode or wait 30 seconds for normal display to
appear
C. Auto Heat Operation.
Your spa is equipped with a 2-speed pump. The low
speed operates during filtration and heating cycles. Your
selected water temperature will be maintained
automatically 24 hours a day. The electronic thermostat
will monitor your water temperature at the top of each
hour by cycling the low speed pump for 2 minutes. If the
spa water temperature is below the set temperature, the
heater will be activated until the water temperature
reaches the set temperature, at which point both low
speed pump and heater will turn off. If the water
temperature is at the set temperature, the low speed
pump will turn off at the end of the 2 minutes..
The spa water will heat at about 2 deg F per hour. Your
selected water temperature will be maintained 24 hours
a day. The maximum temperature is set at 104° F. Note
that the heater will turn off when you are using the spa
on therapy mode (Hi-speed of the pump). The heater
only operates on low speed.
In case of an electrical power failure or if you disconnect
your spa, the selected temperature and current time will
be stored in memory. Once the power is restored, your
spa will continue to operate as per your original choice.
The time setting will obviously have to be corrected.
D. Jet Operation
The Voyager is equipped with a 2-speed
or 2-mode therapy pump. The soft-mode
(low speed) provides soft Relaxation Therapy and
the power mode (hi-speed) provides vigorous
Power Therapy.
JET Button:
1.
Press "JET" to activate the Relaxation
Therapy mode. (Low speed pump).
2. Press "JET" a second time to activate the
Power Therapy mode. (High speed pump).
3. Press "JET" a third time to turn the pump off.
Note that the heater will turn off during therapy
mode (hi-speed) to allow the spa to continue to
operate on 15A 110V outlet. For safety, all jet
modes will automatically turn off after 30 minutes. If
needed, reactivate any therapy mode as indicated
above. Remember that the low-speed mode is also
controlled by the thermostat and the filtration cycle
timer. The low-speed pump will remain on if the
thermostat calls for heat or if you are operating
the spa during the auto filtration cycle (8am to
11am & 4pm to 7pm).
ALWAYS CHECK THE WATER TEMPERATURE