Sundance Spas 850 Series Hot Tub User Manual


 
Table No. 1
POWER SUPPLY OPTIONS AND REQUIREMENTS
Sundance hot tubs are designed to provide optimum performance and flexi-
bility of use when connected to the maximum electrical service as listed
below. However, they are shipped configured for the most commonly pre-
ferred electrical connection -- 50A, 240V*
If you prefer, your Sundance dealer can perform a minor circuit board modifi-
cation to allow the hot tub to accept different electrical service. The opera-
tional considerations of these modifications are listed in the footnotes below.
CAMEO, OPTIMA, MARIN and ALTAMAR MODELS
240V/30A** 240V/50A* 240V/60A***
Voltage 240 volts 240 volts 240 volts
Current Draw 24 amps 40 amps 48 amps
Number of Wires Three Three Three
Circuit Breaker 30A dual pole 50A dual pole 60A dual pole
CAPRI
240V/30A** 240V/50A* 240V/60A***
Voltage 240 volts 240 volts N/A
Current Draw 24 amps 40 amps
Number of Wires Three Three
Circuit Breaker 30A dual pole 50A dual pole
* In 50A configuration, the heater will not operate while both pumps are
operating at high speed. Note: pump 2 runs only in high speed.
** In 30A configuration, the heater will not operate while either pump is
running in high speed or if the air blower is running. Note: pump 2 runs
only in high speed.
*** In 60A configuration, the heater will operate at the same time as the
high speed of both pumps and the air blower. Note: Not applicable for
1-pump Capri models.
Page 12