13.4 Panel displays SN2
Open or shorted sensor (heater disabled). The temperature
sensor is not functioning. Your authorized dealer must repair
this.
13.5 Panel displays FL1 or FL2
A ashing “FL1” display means the ow switch is
malfunctioning open, the circulation pump’s lter
cartridge is excessively dirty, or an “air lock” condition
has occurred at the circulation pump intake. A ashing “FL2” display
means the ow switch is malfunctioning closed.
This error will cause the heater to deactivate. The main pump #1 may
also deactivate.
This problem is caused by an interruption in water ow from an
excessively dirty lter cartridge, an “air lock” condition at the pump
intake, or by a malfunctioning ow switch.
To Correct Condition:
1. Verify water level is above all jets and below lowest pillow.
Add water if necessary.
2. Check for clogged/excessively dirty lter cartridge. See
Section 11.1 (pages 35-36).
3. Purge “air lock” from circulation pump intake by removing the lter
cartridge. Hold your garden hose over the lter wall tting (with grate)
using a rag as a seal around hose end, then ask a helper to turn
on water for 30 seconds, then turn off. Reinstall lter cartridge and
check spa. See Section 11.1 (pages 35-36).
4. If the circulation pump is not running, turn power off at the main
breaker, then turn power back on. This will reset the circulation pump
priming cycle. Once the pump is primed, the error should clear.
5. If problem persists, contact your authorized dealer.
13.6 Panel displays COL
Cool Condition - Temperature has dropped 20°F (11°C)
below the current set temperature. The pump and heater have been
activated to bring the temperature to within 15°F (8°C) of the set
temperature. No corrective action is required (page 33).
Note: During cold periods, you may consider increasing the number of
ltration cycles.
13.7 Panel displays ICE
Freeze Protection - A potential freeze condition has been
detected. No action is required. Main pump will operate to
circulate warm water through the plumbing until the spa is out of danger.