Sundance Spas 6530-512X Hot Tub User Manual


 
Page 44
ELITE SERIES
13.0 Error Conditions/Error Messages
There are a number of unique functions designed into your spa to protect
it from damage and/or aid in troubleshooting. Refer to Sections 13.1-13.8
below for a listing of all possible error messages and their meanings.
13.1 Summer Logic
When the actual spa water temperature reaches up to 2°F
(1°C) above the set temperature, the spa goes into
“summer logic”. The circulation pump will turn off
automatically, if running, to avoid adding additional heat
to the water, eventually creating an overheat condition. This
setting is not user-programmable.
Note: The summer logic does not take effect until the spa water
temperature reaches 95°F (35°C). This condition is more likely in
excessively hot weather. Remember, the spa’s ability to cool is directly
affected by the ambient temperature. An excessively hot ambient
temperature may prevent the spa from cooling down because it’s
fully insulated construction is designed to retain heat and to minimize
operating costs.
13.2 Overheat Condition
WARNING: RISK OF HYPERTHERMIA (OVER-HEATING)
CAUSING SEVERE INJURY, BURNS, OR WELTS.
!
DO NOT ENTER SPA WATER! Water is too hot. Overheat
protection. Heater is deactivated. Spa water temperature
is above acceptable limits.
When the actual water
temperature is approximately 2°F (1°C) above the set temperature, the
circulation pump will stop operating to reduce (frictional) heating. To
correct condition, remove spa cover to speed cooling. (CAUTION! Never
leave spa uncovered when children are present!) If condition persists,
contact your authorized Sundance dealer.
13.3 Panel displays SN1
Open sensor (heater is disabled) or shorted sensor (spa is
deactivated). The high-limit temperature sensor is not
functioning. Your authorized dealer must repair this.