Sundance Spas 6530-512X Hot Tub User Manual


 
Page 18
ELITE SERIES
Decontamination Procedure (Steps 9-15)
Steps 9-15 below are only required when sanitizer levels are unstable
after performing steps 1-6 above. Disregard steps 9-15 below if sanitizer
levels remain stable at 3.0-4.0 ppm chlorine or 2.0-4.0 ppm bromine
after performing steps 1-6 above.
9. Add 2.5 ounces (71 g) of sodium dichlor for every 100 gallons (378
Liters) of water. Refer to the table for approximate water ll volume
by model.
CAUTION: RISK OF PERSONAL INJURY OR SPA DAMAGE!
Never add chlorine tablets (trichlor) or acid to your hot tub for
any reason! These chemical may damage components within
your hot tub, burn or irritate your skin, create a rash, and void
the manufacturer warranty for your spa.
!
Water Fill Capacity by Model
Average Sodium
Model Fill Volume* dichlor
Constance ...................... 375 Gal (1,419 L) .................................. 9.5 oz
Victoria ............................ 410 Gal (1,552 L) ..................................10.0 oz
*Use average ll volume for chemical maintenance.
10. Leave spa cover open during this step to allow
excessive chemical vapors to exit spa, protecting
pillows and plastic knobs from chemical attack. If spa is
indoors, open doors and windows for proper ventilation.
Turn on all spa jets pumps for one hour, open all air
controls, and place all massage selector knob(s) in their center
“combo” position as shown (right).
Note: You will need to press the jets pump button(s) every 20 minutes
since these functions have an automatic 20 minute time-out function that
turns them off.