Shindaiwa DG1000MI Portable Generator User Manual


 
- 42 -
10.4 Draining Water from Water Separator
When a float (red) is at drain level, drain water.
Loosen the drain plug and drain water.
Screw the drain plug, when finishing drain.
<Caution>
After draining finishes, extract the air in fuel line.
(Refer to 9-3 During operation.)
10.5 Cleaning / Changing Fuel Filter
Loosen and remove the fuel filter, using an oil filter wrench
Drain all the water in the fuel filter
Smear a little fuel on the rubber gasket of the new fuel filter
Screw the new filter into place and tighten it until the gasket contacts the seat. Then,
give it additional 2/3 turn to seat the filter, using an oil filter wrench
<Caution>
After replacing the filter, always air out the fuel system (refer to 9-2. During Operation)
Fuel filter element:
ISUZU Part No.
1132400791
Clean Every 200 hours
Replace Every 500 hours