10.3 Cleaning / Changing Air Filter Element
Clean Every 200 hours
Replace Every 500 hours
Loosen the bolt that is holding the air cleaner and remove the cleaner cap
Unscrew the wing nut and remove the filter element
Clean or replace the filter element, and reinstall it in reverse order
<Caution>
Always make sure that the arrow mark on the cleaner cap is pointing upward
Clean more frequently, if used in dusty environment
Air filter element:
ISUZU Part No.
9142151321
To clean the air filter element:
If the element has dried contaminants, it may be
cleaned by blowing compressed air from the inside.
If the element has carbon or grease, it should be
replaced with new element.
Clog Indicator
The clog indicator to display clog in the air filter element
is incorporated to air filter unit.
Whenever RED SIGNAL appears in the indicator
window, clean or change element regardless of
operation hour.
After cleaning or changing finishes, push the reset
button to release the RED SIGNAL.
CLEANER CAP
AIR CLEANER
FIXING BOLT
WING NUT
CLEANER CAP
AIR FILTER ELEMENT
CLOG INDICATOR
RESET BUTTON
WINDOW
(RED SIGNAL)