Shindaiwa DG1000MI Portable Generator User Manual


 
- 21 -
7.2 Connecting Cable
:Electrical Shoc
k
Before connecting or disconnecting a load cable from output terminals, always turn a circuit
breaker to OFF position, stop the engine, and remove the engine key. A person performing
the maintenance should always keep the key.
:
Fire
Do not connect AC output to any indoor wiring.
<Caution>
Divide loads into 3 circuits proportionally as possible, when using the maximum
output power especially, and connect them to each phase (R,S,T) respectively.
Be careful to limit the current under the rated current per the phase .
The 1-Phase terminals and receptacles output power are originated from the R and T
Phase output powers.
7.2.1 Load Connection Terminal Plate (3-Phase)
7.2.1.1 For 3-Phase Load
Terminal Voltage: 200V/220V (or 400V/440V) at 50Hz/60Hz
7.2.1.2 For 1-Phase Load(1)
Terminal Voltage: 115V/127V (or 230V/254V) at 50Hz/60Hz
Danger
Caution
R
S
T
O
Load
R
S
T
O
Load
Load
Load