20
TROUBLESHOOTINGTABLE
TROUBLE CAUSE REMEDY
Engine will not
start or will run
only a few
seconds after
starting.
1. ON/STOP switch in
STOP position.
2. Engine flooded.
3. Fuel tank empty .
4. Spark plug not firing.
5. Fuel not reaching
carburetor.
6. Carburetor requires
adjustment.
7. None of the above.
1. Move ON/STOP switch to ON.
2. See “Difficult Starting” in the
Operation Section.
3. Fill tank with correct fuel mixture.
4. Install new spark plug.
5. Check for dirty fuel filter; replace.
Check for kinked or split fuel line;
repair or replace.
6. Contact Sears Service (see back cover).
7. Contact Sears Service (see back cover).
Engine will
not idle
properly.
1. Idle speed set too high
or too low.
2. Low Speed Mixture
requires adjustment.
3. Crankshaft seals worn.
4. Compression low.
5. None of the above.
1. See “Carburetor Adjustment” in the
Service and Adjustments Section.
2. Contact Sears Service (see back cover).
3. Contact Sears Service (see back cover).
4. Contact Sears Service (see back cover).
5. Contact Sears Service (see back cover).
1. Air filter dirty.
2. Spark plug fouled.
3. Carburetor requires
adjustment.
4. Exhaust ports or muf-
fler outlets plugged.
5. Compression low.
6. Chain brake engaged.
7. None of the above.
Engine will not
accelerate,
lacks power,
or dies under
a load.
1. Clean or replace air filter.
2. Clean or replace plug and regap.
3. Contact Sears Service (see back cover).
4. Contact Sears Service (see back cover).
5. Contact Sears Service (see back cover).
6. Disengage chain brake.
7. Contact Sears Service (see back cover).
Engine
smokes
excessively.
1. Choke partially on.
2. Fuel mixture incorrect.
3. Air filter dirty.
4. High Speed Mixture
requires adjustment.
5. Crankcase leak.
1. Adjust choke.
2. Empty fuel tank and refill with
correct fuel mixture.
3. Clean or replace air filter.
4. Contact Sears Service (see back cover).
5. Contact Sears Service (see back cover).
Engine runs
hot.
1. Fuel mixture incorrect.
2. Spark plug incorrect.
3. High Speed Mixture
set too lean.
4. Exhaust ports or muf-
fler outlets plugged.
5. Carbon build-up on
spark arresting screen.
6. Starter housing dirty
7. None of the above.
1. See “Fueling Engine” in the Operation
section.
2. Replace with correct plug.
3. Contact Sears Service (see back cover).
4. Contact Sears Service (see back cover).
5. Clean spark arresting screen.
6. Clean starter housing area.
7. Contact Sears Service (see back cover).
W ARNING:
Always stop unit and disconnect spark plug before perform-
ing all of the recommended remedies below except remedies that require
operation of the unit.