Subaru Robin Power Products RGXI 800 Portable Generator User Manual


 
11. TROUBLESHOOTING
0
11-l NO AC OUTPUT
11-1-l CHECKING CONDENSER
Check the capacity of condensers using a “Dr. Robin”generator tester in capacitance meter mode.
NOTE : Be sure to discharge condensers by shorting condenser leads each other before checking their
capacitance, or the accurate reading cannot be obtained.
Fig. 11-l
n
NORMAL CAPACITY OF CONDENSER
MODEL RGXl800
RGX2400
RGX3500 RGXSSOO
CAPACIlY
14pF
2fJfiF
17,uFx2
28,uFX2
Table 1 l-l
n
If such an instrument is unavailable,the condenser can be checked by replacing with a new one-If the
generator performs good with new condenser, the cause of trouble is defect in original condenser.
11-l-2 CHECKING STATOR
W Remove control panel and disconnect stator
wires at the connectors.
W Measure the resistance between terminals on
stator leads. (See Fig. 11-2)
Refer to Table 9-l for normal resistance.
If stator is faulty, replace it with a new one.
Fig. 11-2
-
69
-