Use extreme caution near fuel. A constant danger of explosion or fire exists.
Do not fill the fuel tank while the engine is running. Do not smoke or use opem flame near the fuel
tank. Be careful not to spill fuel when refueling. If spilt, wipe it and let dry before starting the engine.
Do not place inflammable materials near the generator.
Be careful not to put fuel, matches, gunpowder, oily cloth, straw, and any other inflammables near the
generator.
Do not operate the generator in
a roorn,cave or tunnel. Always oPerate in a well-ventilated area”
Otherwise the engine may overheat and also, the poisonous carbon monoxide contained in the exhaust
gases will endanger human lives. Keep the generator at least 1 m (4 feet) away from structures or
facilities during use.
Operate the generator on a level surface.
If the generator is tilted or moved during use, there is a danger of fuel spillage and a chance that the
generator may tip over.
Do not operate with wet hands or in the rain.
Severe electric shock may occur. If the generator is wet by rain or snow, wipe
before starting.
Don’t pour water over the generator directly nor wash it with water.
If the generator is wet with water, the insulations will be adversely affected
leakage and electric shock.
Do not connect the generator to the commercial power lines.
it and thoroughly dry it
and may cause current
This may cause a short-circuit or damage to the generator.Use a transfer switch for connecting with
indoor wiring.
NOTE: The patts numbers of the transfer switches and of tie plastic box to store them are as
shown in Table 6-1.
7
Part No. Part Name
Q’ty
Phase Allowable Current
365-45604-08
Transfer Switch 1 1 15A
367-45605-08
Transfer Switch
1
1
30A
340-45606-08
Transfer Switch 1 1 60A
367-43008-08
Plastic Box 1
1 30A
348-43009-08
Plastic Box 1
1
60A
Table 6-1
Use a fuse of the correct capacity. (DC output)
If the generator rpm is increased excessively in the overload condition by using an over rated fuse, the
generator may be burnt.
CAUTION :
If the fuse is burnt or the circuit breaker tripped off as a result of using an
electrical appliance,the cause can be an overload or a short-oircuit. In such a case, stop
operation immediately and carefully check the electrical appliance and AC plugs for faulty
wiring.