Checking table for digital circuit tester.
Apply red @ needle of the circuit tester
Digital circuit tester
Brown Brown Orange Brown/White
Brown
No continuity 1 No continuity Continuity
Apply black 0 needle
of the circuit tester
Brown
drange
No continuity Continuity
Continuity Continuity
I I
.I
Brown/White
No continuity No continuity
No continuity
NOTE I:
Because of the difference of measuring method between the analogue circuit tester and the
digital circuit tester, polarity of tester needles should be reversed.
NOTE 2: “Continuity” means forward direction characteristics of the diode, and different from short
circuit condition (in which a pointer of the tester goes out of its normal scale), shows
resistance to some extent. When results of the checking indicates failure even in one
section,replace with a new one.
NOTE 3:
Simpson brand analogue testers are digital.
Table 9-4-2
IO. DISASSEMBLY AND ASSEMBLY
10-I PREPARATION and PRECAUTIONS
1) Be sure to memorize the location of individual parts when disassembling the generator so that the
generator can be reassembled correctly. Tag the disassembled part with the necessary information to
facilitate easier and smoother reassembly.
2) For more convenience,divide the parts into several groups and store them in boxes.
3) To prevent bolts and nuts from being misplaced or installed incorrectly, place them temporarily back
at their original position.
4) Handle disassembled parts with care; clean them before reassembly using a neutral cleaning fluid.
5) Use all disassembly/assembly tools properly, and use the proper tool for each specific job.
10-2 SPECIAL TOOLS for DISASSEMBLY and ASSEMBLY
REAR COVER PULLER