Subaru Robin Power Products RGXI 800 Portable Generator User Manual


 
n
NORMAL CAPACITY OF CONDENSER
MODEL RGXl BOO
RGX2400
RGX3500
RGX5500
0
14,xF 20,~F
17fiFX2 28,~FX2
Resistance
0
14,~F 20,~F
17pFX2 28fiFX2
Table 9-3
H If such an instrument is unavailable, the condenser can be checked by replacing with a new one.
If the generator performs good with new condenser, the cause of trouble is defect in original
condenser.
9-7 DIODE RECTIFIER
DIODE RECTIFIER
Brown/
White
Orange
Orange 0
II
rl
Brown
Brown
0 II
Brown/White
CIRCUIT TESTER
Fig. 9-9 Fig. 9-10
Circuit inside of the diode rectifiers is as shown in Fig. 9-9. Check continuity between each terminal by
using a circuit tester as shown in Fig. 9-10. The rectifier is normal when condtinuity is as follows:
H Checking table for analogue circuit tester.
Analogue circuit tester
Apply black @needle of the circuit tester
Brown
Brown Orange BrownMlhite
I
Brown
No continuity No continuity Continuity
I I. I I
Apply red @ needle
of the circuit tester
Brown
No continuity
Orange
Continuity
Brown/White
No continuity
Table 9-4-l
- 51 -