Single Structure Installations
Legend for Generator Locations to reduce the risk of fire:
A - Standby weatherproof enclosure must be at least
5 ft. (1.5 m) from windows, doors, any wall opening,
shrubs, or vegetation over 12 inches (30.5 cm)
in height.
B - Exhaust oulet side of weatherproof enclosure
must have at least 5 ft. (1.5 m) minimum clearance
from any structure, overhang or trees.
C - Standby weatherproof enclosure must have a
minimum of 5 ft. (1.5 m) overhead clearance from
any structure, overhang, or trees.
NOTICE DO NOT place weatherproof enclosure under a
deck or other type of coverend structure that may
confine airflow.
Standby
Standby
Exhaust
Direction
Exhaust
Direction
5 ft. (1.5 m)
5 ft. (1.5 m) min
5 ft. (1.5 m) min
5 ft. (1.5 m)
18 in. (45.7 cm) min
Structure
Structure
A A
A
B
B