Multiquip DCA-600SSV Portable Generator User Manual


 
PAGE 26 — DCA-600SSV — OPERATION AND PARTS MANUAL — REV. #0 (07/13/09)
DCA-600SSV — OUTPUT TERMINAL FAMILIARIZATION
Figure 8. Output Terminal Panel
Output Terminal Familiarization
The “
Output Terminal Panel
” (Figure 8) is provided with
the following:
Three 240/139V output receptacles, 50 amp
Three AUX. circuit breakers 240V @50 amps
Two 120V GFCI receptacles, 20 amp
Two (2) GFCI circuit breakers 120V@ 20 amps
Eight (16) output terminal lugs
Output Terminal Panel
Shown below (Figure 8) is the
Output Terminal Panel
, lift
up on the cover to gain access to receptacles and terminal
lugs.
Terminal legs "O" and "Ground"
are considered
bonded grounds
.
NOTE