Kohler 20--2800 kW Portable Generator User Manual


 
TP-5700 7/93
40Section 7 Electrical RequirementsTP-5700 7/93
GENERATOR JUNCTION BOX
SAFEGUARD
CIRCUIT BREAKER
TERMINAL STRIP
(IN JUNCTION BOX)
RUN RELAY
KIT
BATTERY
HEATER KIT
GENERATOR
HEATER KIT
BLOCK
HEATER KIT
AC
CONNECTION
BOX (Installer
Supplied)
BATTERY
CHARGER
KIT
LOW FUEL
SWITCH KIT
10-RELAY DRY
CONTACT KIT
TRANSFER
SWITCH
(OPTIONAL)
REMOTE
ANNUNCIATOR
SINGLE
RELAY DRY
CONTACT KIT
NOTE 1:
HARD WIRED TO GENERATOR BATTERY
NEGATIVEENGINE CONNECTION.
NOTE 2:
FOR REMOTEANNUNCIATOR: “C”
TERMINALS OF THEREMOTE ANNUNCIATOR
DRYCONTACTSMUST BEHARD WIREDTO
THE GENERATORBATTERYNEGATIVE
ENGINE CONNECTION. “P”TERMINAL OF
THE REMOTEANNUNCIATOR DRYCONTACT
MUST BEHARD WIREDTOTHE GENERATOR
BATTERY POSITIVEENGINE CONNECTION.
OPTIONALEQUIPMENT
CUSTOMER
ACCESSORIES
3 WIRES MAX.
18-20 GA.
MUST BE MOUNTED
ATGENERATOR
3 WIRES
18-20 GA.
200 FT.MAX.
3 WIRES
18-20 GA.
GENERATOR BATTERY NEGATIVE
& POSITIVE CONNECTION
2 WIRES 14GA.
SEE NOTE2
1WIRE
18-20 GA.
2 WIRES
18-20 GA.
CUSTOMER
ACCESSORIES
30 WIRESMAX.
18 GA.
GENERATOR BATTERY
NEGATIVE CONNEC-
TION
GENERATOR BATTERY
POSITIVECONNECTION
SEE NOTE1
AC POWER INDEPENDENT
OF GENERATOR
BASED ON
ADV-5795-S-B
AUDIOVISUAL
ALARM KIT
REMOTE
EMERGENCY
STOP KIT
GENERATOR SET
CONTROLLER
CUSTOMER
CONNECTION
KIT
COMMON
FAULT
RELAY KIT
14--RELAY
DRY CONTACT
14 WIRES18-20 GA.
2 WIRES:
100 FT.18-20GA.
500 FT.14 GA.
1000 FT.10 GA.
CUSTOMER
ACCESSORIES
3 WIRES MAX.
18-20 GA.
3 WIRES
18-20 GA.
2 WIRES
18-20 GA.
MUST BE MOUNTED
ATGENERATOR
ENGINE STARTTERMINALS
3 AND4 (OR57 AND58)
REMOTE
START SWITCH
(Installer
Supplied)
Figure 7-9 Generator Set Connections, Typical