Jacuzzi J - 210 Hot Tub User Manual


 
J-200 Series
6.0 Power Requirements
Jacuzzi
®
spas are designed to provide optimum performance and
exibility of use when connected to the maximum electrical service listed
below. Minor circuit board modications can be performed to allow your
new spa to accept an electrical service other than the factory operation
setting.
Note: Refer to pages 44-47 for circuit board conguration details or
contact your authorized Jacuzzi dealer.
All North American J-270 and J-280 Models (60 Hz)
240V/40A* 240V/50A** 240V/60A***
Circuit Breaker (2-Pole): 40A* 50A** 60A***
Number of Wires: 3 3 3
Frequency: 60 Hz 60 Hz 60 Hz
Current Draw: 26A 36A 45A
*
In 40A conguration, the heater will not operate while either jets
pump is running in high speed. Note: pump 2 runs only in high
speed.
**
In 50A conguration, the heater will not operate while both jets
pumps are running in high speed. This is the factory setting.
Note: pump 2 runs only in high speed.
***
In 60A conguration the heater will operate while both jets pumps
are running in high speed.
All North American J-230 Models (60 Hz)
240V/40A* 240V/50A**
Circuit Breaker (2-Pole): 40A* 50A**
Number of Wires: 3 3
Frequency: 60 Hz 60 Hz
Current Draw: 26A 36A
*
In 40A conguration, the heater will not operate while the jets
pump is running in high speed.
**
In 50A conguration, the heater will operate while the jets pump is
running in high speed. This is the factory setting.
13