TROUBLE SHOOTING
FAULT POSSIBLE CAUSE REMEDY
Engine will not start Travel control interlock switch sensor not
energised
Ensure travel control levers are in the neutral
position
Check setting of interlock switch sensor
Ignition control switched off Turn ignition control to the ‘on’ position
Engine switch in the ‘off’ position Turn the ignition switch to the ‘on’ position
Cutterhead drive interlock switch sensor not
engaged
Check setting of cutterhead interlock switch
sensor
Disengage the cutterhead drive
Fuel valve closed Turn the fuel valve to the ‘on’ position
Insufficient ‘choke’ Reset the choke lever
For all other engine problems; refer to ENGINE HANDBOOK
Lack of transmission
drive
Parking brake engaged Release parking brake
Low oil level Fill reservoir to correct level
Air in system Carry out ‘bleeding’ procedure
Incorrect oil used Drain reservoir and refill with correct oil
Drive belt incorrectly tensioned Re tension drive belt
Broken drive belt Replace drive belt
Bypass valve open Close bypass valve
Incorrect linkage adjustment Re adjust linkage setting
Defective hydrostatic unit or transaxle Consult your authorised dealer
Forward / backward
transmission creep in
neutral
Neutral adjustment incorrectly set Re adjust neutral detent mechanism
Transmission system
overheating
Blocked cooling fins Clean fins
Hydrostatic unit oil level low Check reservoir and top up as necessary
Air in hydrostatic system Carry out ‘bleeding’ procedure
Transaxle oil level low Check the dipstick and fill to the correct level
Parking brake engaged Disengage parking brake
Cutterhead drive brake engaged Re adjust brake settings
Defective cooling fan or fan drive Check fan operation and service as required