Remove the clip and stop ring from the thermostatic cartridge stem. Put them in a safe
place.
Turn the thermostatic mixer stem with your fingers, clockwise to make the water cooler,
counter-clockwise to make the water warmer. Turn the stem until the water coming out is the
desired maximum high temperature – 110° in most areas.
Reinstall the stop ring so that it is against the stop. Reinstall the clip.
Justify and reinstall the handle.
Set the high temperature limit stop (optional)
IMPORTANT: Many municipalities have codes limiting the maximum discharge temperature
of a shower valve to 110° F - 112° F or less. In Massachusetts, the maximum output tem-
perature is 112°F. Please know and follow all applicable local codes when setting the high
temperature limit stop.
Tools Required:
Thermometer
3 mm Allen wrench (included with trim kit)
Turn the hot and cold supplies to the valve on.
Turn the water on using the handle.
Use the 3 mm Allen wrench to loosen the set screw on the bottom of the handle. Remove
the handle.