Hans Grohe 06061XX0 Outdoor Shower User Manual


 
3
Technical Information
Recommended pressure 45 - 72 psi
Max hot water temperature 165 F*
Recommended incoming hot water temp. 120° - 140° F*
With rough valve 06621000, 06622000
Nominal capacity @ 45 PSI 9.5 gpm
Nominal capacity @ 60 PSI 11.5 gpm
With rough valve with bypass 06300000, 06301000
Nominal capacity @ 45 PSI 6.0 gpm
Nominal capacity @ 60 PSI 6.5 gpm
Safety stop 100° F
Maximum output temperature 110° F**
1/2” NPT Connections
Listed by UL
*Please know and follow all applicable local plumbing codes when setting the temperature on the water heater.
**The high temperature limit stop may be reset to comply with local plumbing codes. See page 8.
Installation
Turn the water off at the main, or at the stops, before beginning.
Cut the installation box (i-box) so that it extends
1/16” outside the finished wall.
Remove the label. Cut the support arms that
connect the flushing plug to the installation
box. Remove the flushing plug. Do not dis-
card the screws.
Seal the wall around the i-box with
waterproof sealant.
Failure to seal the wall can lead to possible
water damage.
Be sure that the blue sealing
gasket is removed as well.
Failure to remove the gasket
can result in possible damage
to the cartridge and possible
water damage.
English