Justify the handle
Tools required:
Thermometer
3 mm Allen wrench (included with trim kit)
Turn the valve on. Place the thermometer in the
water stream.
Turn the temperature control knob until the water
coming out measures 100° on the thermometer.
Turn the water off using the lever part of the
handle.
Use a 3 mm Allen wrench to loosen the set screw
on the bottom of the handle. Remove the handle
from the valve (1).
Hold the lever in one hand. With the other hand,
turn the temperature control knob approximately
½ turn clockwise (2a). Then, without pressing
inward on it, turn it counter-clockwise until it is
positioned vertically and hits the safety stop (2b).
Reinstall the handle and tighten the set screw (3).
Modify the cartridge
The current ThermoBalance I cartridge has
both a locator tab and a positioning pin. (The
positioning pin is located on the back of the
cartridge, and is not visible in this picture.)
An older ThermoBalance I/ThermoPlus rough
does not have a notch for the locator tab.
Carefully file off the locator tab before install-
ing a current cartridge into an old rough.
English
2
a
b
locator tab