Generac RG03624ANAX Portable Generator User Manual


 
Maintenance
Owner’s Manual for Stationary Emergency Generators 31
5.7 — Schedule A Maintenance
NOTE: Perform Schedule A maintenance once each year or after 125 hours of service, whichever comes first.
NOTE: The 2.4L (32 kW) unit is depicted in the artwork used in this manual. For the general location of compo-
nents in all other models, see Subsection 5.7.1—Schedule A Maintenance Item Locations.
5.7.1— Schedule A Maintenance Item Locations
NOTE: The side of the enclosure with the viewing window is identified as the rear of the generator set. The
right and left sides are identified by standing at the rear and looking towards the front of the unit.
5.7.2— Preliminary Instructions
1. See Subsection 5.4 —Remove From Service.
2. Remove left and right side access panels. See Subsection 5.2 —Access Panels.
3. Remove battery negative cable (black) from battery negative (-) terminal.
5.7.3— Check Enclosure Louvers
1. Verify that intake and exhaust louvers and openings are clean and unobstructed. Keep clear of leaves, grass,
snow, and debris.
2. Wipe exterior surfaces clean using a damp cloth.
3. Loosen dirt, oil, etc. with a soft bristle brush.
4. Remove loose dirt and debris using a vacuum cleaner, or low pressure compressed air (not exceeding 25 psi).
NOTE: Periodically wash and wax enclosure using automotive type products. Frequent washing is recom-
mended in salt water/coastal areas.
5.7.4— Check Fuel Lines
1. Check fuel lines for leaks. Tighten fittings and clamps, if necessary.
2. Check fuel lines for nicks, dents, kinks or other damage. Replace as necessary.
Model 22/27 kW 25/30 kW 32/38 kW 36/45 kW 48 kW 60 kW
Engine 2.4L 1.5L 2.4L 2.4L 5.4L 2.4L
Coolant Overflow Reservoir
LLLLLL
Oil Dipstick
RRRRLR
Oil Drain Hose
LRLLRL
Oil Filter
RRRRLR
Oil Fill Cap
EEEERE
Oil Supply Tank Fill Cap
---TL-TL
Battery
LRLLRL
Fan Belt
EEEEEE
Air Filter Element
LRLLEL
R = Right Side L = Left Side E = Either Side T = Top - = Not Applicable