Exmark Turf Tracer HP Lawn Mower User Manual


 
- 12 -
2.11.2 Overall Length: 36” 48” 52”
77.7” 73.7” 75.9”
(196 cm) (185 cm) (191 cm)
2.11.3 Curb Weight: 36” 48” 52”
565 lbs. 610 lbs. 644 lbs.
(211 kg) (277kg) (292 kg)
Weights will vary slightly depending on engine and electric start options.
2.11.4 Overall Height: 44.1” (112 cm) (all models)
2.11.5 Tread Width (to outside of tires):
36” Model......................... 35.0” (88.9 cm)
48” Model......................... 39.4” (100.1 cm)
52” Model......................... 39.4” (100.1 cm)
2.12 TORQUE REQUIREMENTS
BOLT LOCATION TORQUE
Blade Mounting Bolt......................................................... 55-60 ft-lbs. (75-81 N-m)
Cutter Housing Spindle Nut ............................................. 140-145 ft-lbs. (190-197 N-m)
Anti-Scalp Roller Bolts...................................................... 40-45 ft-lbs. (54-61 N-m)
Mower Deck Support/Engine Deck Mount........................ 30-35 ft-lbs. (41-47 N-m)
Engine Mounting Bolts .................................................... 15-20 ft-lbs. (20-27 N-m)
Wheel Lug Nuts ............................................................... 90-95 ft-lbs. (122-129 N-m)
Wheel Hub Slotted Nut..................................................... minimum 100 ft-lbs. (136 N-m)
3. ASSEMBLY INSTRUCTIONS
3.1 Uncrate Unit: Remove upper handle assembly, fuel tank, and linkages from the top of
the crate.
3.2 Service Battery
:
The machine is shipped with a filled lead acid battery.
3.2.1 Remove battery cover from the machine.
DANGER
POTENTIAL HAZARD
Charging the battery may produce explosive gasses
WHAT CAN HAPPEN
Battery gasses can explode causing serious injury.
HOW TO AVOID THE HAZARD
Keep sparks, flames, or cigarettes away from battery.
Ventilate when charging or using battery in an
enclosed space.
Make sure venting path of battery is always open once
battery is filled with acid.
3.2.2 Check the voltage of the battery with a digital voltmeter. Locate the voltage reading
of the battery in the table below and charge the battery for the recommended time
interval to bring the charge up to a full charge of 12.6 volts or greater.
IMPORTANT: Make sure the negative battery cables are disconnected and the
battery charger used for charging the battery has an output of 16 volts and 7
amps or less to avoid damaging the battery (see chart below for recommended
charger settings).
WARNING: Battery posts, terminals, and related accessories contain lead compounds, chemicals known
to the State of California to cause cancer and reproductive harm. Wash
hands after handling.