Dayton 3WY46 Portable Generator User Manual


 
Dayton Operating Instructions and Parts Manual 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46
20
Dayton Professional-Duty
Electric Generators
®
Wiring Diagrams
Figure 38 – Wiring Diagram, Models 3WY45 and 3WY46
Figure 39 – Wiring Diagram, Model 3WY47
250V 30A
Receptacle
250V 50A
Receptacle
125V, 15A
Receptacle
GFCI 125V, 15A
Receptacle
125V, 30A
Receptacle
Circuit
Breaker
20A
Circuit
Breaker
20A
Green
Green
Black
Black
White
Black
Red
Black
Black
Black Black
Black
WhiteWhite
White
Green
Black
Black
Black
Red
Red
Red
Red
Yellow
Yellow
White
White
Auto-Idle
Control Board
Yellow
WhiteWhite
White
Circuit
Breaker
30A
Circuit
Breaker
30A
Circuit
Breaker
45A
Circuit
Breaker
45A
Green
T2
Green
Black
Red
White
Main
Windings
T1
T3
T4
Wh
T1 T2T3T4
Rotor
Diode
Diode
Stator
Capacitor
White
White
Run
Light
Hour Meter
Green
L1
S2
Solenoid
S1
T1-3
L2
To
Auto-Idle
Solenoid
Stator
110/120V
T1 T2 T3 T4
L2
L1
110/120V
220/240V
Circuit
Breaker
25A
120/240V 20A
Receptacle
T4
120V, 15A
Receptacle
120V, 30A
Receptacle
White
White
Green
Black
Red
Black
Red
Black
White
T3
Red
Green
Stator
110/120V
T1
T2
T3
T4
L2
L1
110/120V
220/240V
Rotor
Stator
White
Brown
Auxiliary
Phase
Diode
T2
Green
Red
Black
Yellow
Main
Windings
T1
T3
T4
T1
T1
T2
T3
T4
Green/Yellow
Yellow
Red
Black
Green
Diode
Capacitor
White
White
GFCI
Circuit
Breaker
20A
LINE
WHITE
HOT
Circuit
Breaker
25A
Circuit
Breaker
20A
Green
120V, 15A
Receptacle
White
Black
Duplex
White
To Solenoid
s
1
s
2
Full Pwr
Selector
Switch
T2
Red
Black
Black
Red
White
Hour
Meter
Black
White