Dayton Operating Instructions and Parts Manual 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46
2
Dayton Professional-Duty
Electric Generators
®
Specifications
ELECTRICAL SPECIFICATIONS
Rated Rated Amperage Rated Amperage
Model Wattage* 120V 240V
3W735B 2,200 18.3 —
3W736C 4,000 33.3 16.7
3WY44 5,000 41.7 20.8
3WY46 5,000 41.7 20.8
3TE27A 6,000 50 25
3WY45 7,000 60 30
3WY47 10,000 83.3 41.7
* Single-phase, 1.0 power factor
NOTE: Ratings apply to SAE standard conditions. Reduce ratings 3
1
/2% for each 1000 feet above sea level and 1% for each 10°F rise
above 60°F.
Honda Honda Fuel Fuel Tank Oil Alert Electric Weight
Model Engine H.P. Model Type Capacity System Start (pounds)
3W735B 5.5 GX160K1VX Gasoline 3.9 qt. Yes No 85
3W736C 8 GX240K1VA Gasoline 5 gal. Yes No 139
3WY44 9 GX270VA Gasoline 8 gal. Yes No 173
3WY46 9 GX270VDE Gasoline 8 gal. Yes Yes 175
3TE27A 11 GX340K1VA Gasoline 8 gal. Yes No 191
3WY45 13 GX390K1VXE Gasoline 8 gal. Yes Yes 247
3WY47 20 GX620VXA3 Gasoline 13 gal. Yes Yes 347
GENERAL SPECIFICATIONS
120V 120V, 30-Amp 120/240V, 20-Amp 120/240V, 30-Amp 120/240V, 50-Amp 120V Full
Model Duplex Twist-Lock Twist-Lock Twist-Lock Receptacle Power Switch
3W735B Yes No No No No No
3W736C Yes Yes Yes No No Yes
3WY44 Yes Yes Yes No No Yes
3WY46 Yes Yes Yes No No Yes
3TE27A Yes Yes Yes No No Yes
3WY45 Yes Yes No Yes No No
3WY47 Yes Yes No Yes Yes No
RECEPTACLE SPECIFICATIONS
ELECTRICAL COMPONENT SPECIFICATIONS
Resistance in Ohms
Stator Stator Rotor Rotor Capacitor,
Main Auxiliary Primary Secondary MFD Diodes (2)
Model Winding * Winding ∆ Winding † Winding † 450 Volt 800 Volt
3W735B 1.95 5.2 6.79 1.31 16 6 Amp
3W736C 0.71 2.17 0.54 2.07 40 70
3WY44 0.54 1.38 0.61 2.29 50 70
3WY46 0.54 1.38 0.61 2.29 50 70
3TE27A 0.37 1.01 0.68 2.57 60 70
3WY45 0.28 0.78 0.77 2.9 70 70
3WY47 0.40 0.90 0.37 0.50 80 70
(*) Connect T2 (Green) and T3 (Black). Measure resistance between T1 (Red) and T4 (Yellow).
(∆) Resistance between brown and white leads.
(†) Remove diodes to check resistance.