Cooper Bussmann 858 Landscape Lighting User Manual


 
DOCUMENT 1025
REV. B
Instruction Manual
AGS-LED
858 LED Series
Sizes 1, 2, 3, 4 and 5
53
D4
(Red)
D7
(Red)
D11
(Green)
D29
(Green)
Fault
ON ON ON ON Output open circuit
ON OFF ON ON Output Voltage is less than or equal to 75% of Calibrated
Output Voltage or Output Voltage is greater than or equal
to 125% of Calibrated Output Voltage.
OFF ON ON ON Input current < 2.5A or Input current > 6.7A
OFF OFF ON OFF +3.3 Volt Supply Failure
OFF OFF OFF OFF +15 Volt Supply and/or +3.3 Volt Supply Failure (assumes
the main AC power is applied to the power supply board)
Table 12. Power Supply Faults