Briggs & Stratton 60000 Portable Generator User Manual


 
22
Generator AC Connection System
A single-phase, three-wire AC connection system is used
in the generator. The stator assembly consists of a pair of
stationary windings with two leads brought out of each
winding. The junction of leads 22 and 33 forms the neutral
lead, as shown schematically and as wiring diagram. A
complete schematic and wiring diagram can be found later
in this manual.
Neutral is not bonded to ground at generator.
When making connections, obey wire type and torque
specifications shown on the circuit breaker and neutral/
ground connector.
10 A
10 A
240 VAC
NG
120 V
120
V
240 V
44
44
11
11
22
33
Neutral
To Transfer Switch
Control
Board
Ground
Power Winding
Circuit
Breaker
Line 1
Optional
Water
Heater
Neutral
Neutral
To Transfer Switch
Utility Fuse Connection
Line 2 Ground
NOT
for
REPRODUCTION